control:programs
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
control:programs [2022/11/25 10:57] – marilisebester_gmail.com | control:programs [2023/04/11 06:53] (current) – marilisebester_gmail.com | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Control - Programs ====== | ====== Control - Programs ====== | ||
+ | |||
+ | =====Trouble Shooting===== | ||
+ | |||
+ | ====Two programs with the same Mainline running==== | ||
+ | |||
+ | Farmsync cannot run two programs using the same Mainline simultaneously. Both programs will start, but they will not be able to stop. | ||
+ | |||
+ | To set this right, the system must be reset. Please contact a Farmsync Technician to assist. | ||
+ | |||
+ | In order to prevent this from happening again, please make use of the Priority Function under the " | ||
+ | |||
+ | How does the Priorities work: | ||
+ | * Select the relevant Mainline from the dropdown list. | ||
+ | * Enter a priority from 1 to 10, 1 being the highest & 10 being the lowest. | ||
+ | * Farmsync will give priority to the program with the highest priority rating. | ||
+ | * Any program currently running & that has a lower priority rating will be paused, | ||
+ | * & the higher priority program will be allowed to run until the runtime is complete, | ||
+ | * after which the program that was paused will be resumed. | ||
+ | |||
+ | ====Program shows running but physical equipment is offline==== | ||
+ | This usually occurs with Pump Start Units, or systems " | ||
+ | |||
+ | * Refresh the station connected to the Program | ||
+ | * If program still shows " | ||
+ | * Take a video of the controller lights & send to a Farmsync Technician for further assistance | ||
+ | |||
+ | |||
+ | =====Control Screen===== | ||
{{ : | {{ : | ||
Line 9: | Line 37: | ||
* **E:** Total Runtime (minutes) | * **E:** Total Runtime (minutes) | ||
- | {{ : | + | {{ : |
+ | ====Program Control==== | ||
* **A:** " | * **A:** " | ||
* **B:** " | * **B:** " | ||
* **C:** " | * **C:** " | ||
* **D:** " | * **D:** " | ||
- | * **E:** " | + | * **E:** " |
+ | =====Control Display===== | ||
+ | ==== Steps ==== | ||
+ | |||
+ | Clicking the arrow button on the left side of the program name will expand the program to view more detail: | ||
+ | {{ : | ||
+ | |||
+ | * **A:** Here you van view all the steps that make up the Valve Program. It is also indicated which steps are Grouped together. | ||
+ | * **B:** The step that is running will automatically expand to give live readings of: | ||
+ | * Valve Name | ||
+ | * Runtimes (min) | ||
+ | * Flow rate (m3/h) | ||
+ | * Status | ||
+ | * Moisture % | ||
+ | * **C:** List of pumps in the program, each indicating: | ||
+ | * Pump Name | ||
+ | * Status | ||
+ | * Current (Amps) | ||
+ | * Pressure (Bar) | ||
+ | * **D:** Should the program include Fertigation, | ||
+ | * Fertilizer name | ||
+ | * Status | ||
+ | * Flow Rate (L/h) | ||
+ | * Injection Rate (L/m3) | ||
+ | * Current Total (L) | ||
+ | * Requested (L/m3) | ||
+ | * Tank Level (L) | ||
+ | * Out (%) | ||
+ | * EC | ||
+ | |||
+ | ==== Flow Control ==== | ||
+ | To the right, you will be able to see the above " | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | ==== Sensors ==== | ||
+ | All the sensors connected to the Controller active during this program will be listed to the right, along with their values. | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Pump Details ==== | ||
+ | |||
+ | {{ : | ||
+ | The above will be displayed for each pump on the program. | ||
+ | * Pump Program Name | ||
+ | * Program Status (Running / Paused / Stopped) | ||
+ | * Pump Status (Running / Paused / Stopped) | ||
+ | * Current (Amps) | ||
+ | * Flow Rate (m3/h) | ||
+ | |||
+ | ==== Fertilizer Details ===== | ||
+ | |||
+ | {{ : | ||
+ | The above will be displayed for each fertilizer on the program. | ||
+ | * Fertilizer Program Name | ||
+ | * Program status (Running / Paused / Stopped / Alarm) | ||
+ | * Fertilizer Status (Running / Paused / Stopped / Alarm) | ||
+ | * Fertilizer Tank Level (L) | ||
+ | * Mainline Flow Rate (m3/h) | ||
+ | * Fertilizer Total Flow (L) | ||
+ | * Fertilizer Flow Rate (L/h) | ||
+ | * Fertigation Mixture Flow Rate (L/m3) |
control/programs.1669373828.txt.gz · Last modified: 2022/11/25 10:57 by marilisebester_gmail.com