 ====Fertilizer Details==== ====Fertilizer Details====
 +
 +{{ :programs:fert_details.png?nolink&400|}}
 +
   * A: “Name” – Enter a Name for your program   * A: “Name” – Enter a Name for your program
   * B: “External Reference” – For FARMSYNCTM internal use only   * B: “External Reference” – For FARMSYNCTM internal use only
Line 34: Line 37:
   - EC - EC control by injecting Fertilizer at a calculated rate to maintain a specified EC value / Stops after reaching a specified Runtime(min)   - EC - EC control by injecting Fertilizer at a calculated rate to maintain a specified EC value / Stops after reaching a specified Runtime(min)
    
-  * E: “Fertilizer” – Select the relevant Fertilizer from the dropdown list +  * E: “Fertilizer” – Select the relevant Fertilizer from the dropdown list 
 + 
 +====Program Details - continued==== 
 + 
 +{{ :programs:fertilizer_program_details2.png?nolink&350|}} 
 + 
 +  * I: “Mainline Flow Total Sensor” – Select the relevant water meter sensor from the dropdown list 
 +  * J: “Mainline Pressure Sensor” – Select the relevant pressure sensor from the dropdown list 
 +  * K: “Mainline min Pressure (Bar)” – Enter the min pressure required in the Mainline  
 +  * N: “Channel Select Port” – Should there be a pump installed between the Storage Tanks & the channels, providing positive pressure on the channel (in cases where the tanks are not installed at a appropriate height), select that pump from the dropdown list 
 + 
 + 
 + 
 + 
 + 
 +=====Flow Sensor===== 
 +{{ :programs:flow_sensor_settings.png?nolink&400|}} 
 +  * A: “Fertilizer Tank Level Sensor” – Select the relevant Tank Level Sensor from the dropdown list 
 +  * B: “L/Pulse” – Enter the Pulse Rating of the water meter installed 
 +    *  0:1 = 1L 
 +    *  0:0.1 = 0.1L 
 +  * C: “Fertilizer Flow Sensor” – Select the relevant Fertilizer water meter sensor from the dropdown list 
 +  * D: “Fertilizer Flow Rate Sensor” – Select the relevant Flow Rate sensor from the dropdown list 
 +    *  If Flow Rate Sensor is connected to the Controller, an option from the dropdown list may be chosen 
 +    *  If Flow Rate Sensor is connected to the Expander, select “Not Set” from the dropdown list 
 +  * E: “Calculate Flow from Slave” – 
 +  * F: “Fertigation Rate Flow Sensor” – Select the relevant sensor from the dropdown list 
 +  * G: “Mainline Flow Sensor” – Select the relevant Mainline Flow Sensor from the dropdown list 
 + 
 +=====Agitating===== 
 +{{ :programs:agitating.png?nolink&400|}} 
 + 
 +A – D settings are for Agitating DURING Fertigation 
 +  * A: “Agitating Duration (sec)” – Enter the duration of Agitation  
 +  * B: “Agitating Interval (sec)” – Enter the duration of time that must pass before Agitating again 
 + 
 +  * C: “Agitate Before Applying” – Tick this box to Agitate before applying Fertigation 
 +  * D: “Agitate While Applying” – Tick this box to Agitate while applying Fertigation *Will agitate the entire time fertigation program is active (leave A & B clear) 
 + 
 +  * E: “Agitating Port” – Select the relevant port connected to the Agitator 
 + 
 +F – G settings are for Agitating when not Fertigating 
 +  * F: “Auto Agitating Duration (sec)” – Enter the duration of Agitation 
 +  * G: “Auto Agitating Interval (sec)” – Enter the duration of time that must pass before Agitating again 
 +  * H: “Agitation Program” -  
 + 
 +=====EC Control===== 
 +The values entered here for EC min & Max are used for the EC Alarms if the Enable Alarm on EC Critical is active 
 +{{ :programs:ec_control.png?nolink&400|}} 
 + 
 +  * A: “EC Min” – Enter the min EC value allowed  
 +  * B: “EC Target” – Enter the Target EC value 
 +  * C: “EC Max” – Enter the max EC value allowed 
 +  * D: “EC Compensation (%)” –  
 +  * E: “EC Compensation Adjustment (%)” -  
 + 
 +=====Alarms===== 
 +{{ :programs:fert_alarms.png?nolink&400|}} 
 + 
 +====Fertilizer Flow Rate Alarms==== 
 +  * A: “Alarm on Low Tank Level” – Tick to enable alarm on Low Tank Level 
 +  * B: “Enable Fertilizer Flow Rate Alarm” – Tick to enable Flow Rate Alarm set on Fertilizer 
 +  * C: “Flow Fertilizer Rate Error (%)” – Enter percentage Flow Rate allowed to be higher than expected before alarm is triggered 
 +    * Note: this percentage is the inverted; meaning if the expected Flow Rate is 100L/h, & Error is set to 80%, the alarm will be triggered on 100L/h + 20% = 120L/h 
 +  * D: “Alarm on EC Error” – Tick this box to enable alarm on EC Error 
 +  * E: “Alarm on PH Error” – Tick this box to enable alarm on PH Error 
 +  * F: “Fertilizer Alarm Duration Threshold (sec)” – The duration of time allowed for the Fertilizer programs values to be higher than margins allow before the alarm is triggered 
 +  * G: “Uncontrolled Alarm Amount (L)” – Max Volume of Fertilizer allowed to pass during one dose before alarm is triggered  
 +    * This alarm is for when the Fert Valve does not close (overdosing) 
 +    * Or when there is a leak  
 + 
 +====Fertilizer Pump Alarms==== 
 +  * H: “Fert Pump Start Delay (sec)” – Enter the pump start delay here  
 +  * I: “Fert Pump Alarm Sensor” – Select the relevant sensor from the dropdown list  
 +  * J: “Fert Pump Alarm Min” – Enter the min value allowed for sensor selected 
 +  * K: “Fert Pump Alarm Max” – Enter the max value allowed for sensor selected 
 + 
 +=====Output Control===== 
 +{{ :programs:output_control.png?nolink&400|}} 
 +  * A: “Max Catchup (%)” –  
 +  * B: “Output Rate Control”  
 +    *  “Always On” – used during batching, keeps the dosing valve open 
 +    *  “Analog VSD Output” –  
 +    *  “Duty Cycle” – used during proportional dosing, opens & closed the dosing valves based on values entered in C – E 
 +    *  “Pulse Frequency” –  
 +    *  “On/Off Delay” – used during proportional dosing, opens & closed the dosing valves based on values entered in C - E 
 +  * C: “Min Injector Off Delay (sec)” –  
 +  * D: “Min Injector On Delay (sec)” –  
 +  * E: “Control Cycle Duration (sec)” –  
 + 
 +======Adding Fertilizer to Valve Program====== 
 + 
 +=====Adding a Fertilizer Program to a Step===== 
 +Each “Step” has provision to add Fert Programs. 
 +{{ :programs:fert_to_step.png?nolink&400 |}} 
 + 
 +  * A: To add a Fertilizer program to the Valve Program, click on the “+”  
 + 
 +{{ :programs:fert_step_details.png?nolink&400 |}} 
 + 
 +  * As seen above, you can now enter the following specifications: 
 +    * "Liters" - if dosing according to a batching method 
 +    * "L/m3" - if dosing according to a proportional method 
 +    * "EC" - if dosing to maintain a certain EC 
 +    * "Pre-Delay" - duration of time that must pass from start of irrigation until fert program starts 
 +    * "Post-Delay" - duration of time that the fert program must stop before the irrigation program stops 
  