Line 41: | Line 41: | ||
====Program Details - continued==== | ====Program Details - continued==== | ||
- | {{ : | + | {{ : |
* I: “Mainline Flow Total Sensor” – Select the relevant water meter sensor from the dropdown list | * I: “Mainline Flow Total Sensor” – Select the relevant water meter sensor from the dropdown list | ||
Line 47: | Line 47: | ||
* K: “Mainline min Pressure (Bar)” – Enter the min pressure required in the Mainline | * K: “Mainline min Pressure (Bar)” – Enter the min pressure required in the Mainline | ||
* N: “Channel Select Port” – Should there be a pump installed between the Storage Tanks & the channels, providing positive pressure on the channel (in cases where the tanks are not installed at a appropriate height), select that pump from the dropdown list | * N: “Channel Select Port” – Should there be a pump installed between the Storage Tanks & the channels, providing positive pressure on the channel (in cases where the tanks are not installed at a appropriate height), select that pump from the dropdown list | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | =====Flow Sensor===== | ||
+ | {{ : | ||
+ | * A: “Fertilizer Tank Level Sensor” – Select the relevant Tank Level Sensor from the dropdown list | ||
+ | * B: “L/ | ||
+ | * 0:1 = 1L | ||
+ | * 0:0.1 = 0.1L | ||
+ | * C: “Fertilizer Flow Sensor” – Select the relevant Fertilizer water meter sensor from the dropdown list | ||
+ | * D: “Fertilizer Flow Rate Sensor” – Select the relevant Flow Rate sensor from the dropdown list | ||
+ | * If Flow Rate Sensor is connected to the Controller, an option from the dropdown list may be chosen | ||
+ | * If Flow Rate Sensor is connected to the Expander, select “Not Set” from the dropdown list | ||
+ | * E: “Calculate Flow from Slave” – | ||
+ | * F: “Fertigation Rate Flow Sensor” – Select the relevant sensor from the dropdown list | ||
+ | * G: “Mainline Flow Sensor” – Select the relevant Mainline Flow Sensor from the dropdown list | ||
+ | |||
+ | =====Agitating===== | ||
+ | {{ : | ||
+ | |||
+ | A – D settings are for Agitating DURING Fertigation | ||
+ | * A: “Agitating Duration (sec)” – Enter the duration of Agitation | ||
+ | * B: “Agitating Interval (sec)” – Enter the duration of time that must pass before Agitating again | ||
+ | |||
+ | * C: “Agitate Before Applying” – Tick this box to Agitate before applying Fertigation | ||
+ | * D: “Agitate While Applying” – Tick this box to Agitate while applying Fertigation *Will agitate the entire time fertigation program is active (leave A & B clear) | ||
+ | |||
+ | * E: “Agitating Port” – Select the relevant port connected to the Agitator | ||
+ | |||
+ | F – G settings are for Agitating when not Fertigating | ||
+ | * F: “Auto Agitating Duration (sec)” – Enter the duration of Agitation | ||
+ | * G: “Auto Agitating Interval (sec)” – Enter the duration of time that must pass before Agitating again | ||
+ | * H: “Agitation Program” - | ||
+ | |||
+ | =====EC Control===== | ||
+ | The values entered here for EC min & Max are used for the EC Alarms if the Enable Alarm on EC Critical is active | ||
+ | {{ : | ||
+ | |||
+ | * A: “EC Min” – Enter the min EC value allowed | ||
+ | * B: “EC Target” – Enter the Target EC value | ||
+ | * C: “EC Max” – Enter the max EC value allowed | ||
+ | * D: “EC Compensation (%)” – | ||
+ | * E: “EC Compensation Adjustment (%)” - | ||
+ | |||
+ | =====Alarms===== | ||
+ | {{ : | ||
+ | |||
+ | ====Fertilizer Flow Rate Alarms==== | ||
+ | * A: “Alarm on Low Tank Level” – Tick to enable alarm on Low Tank Level | ||
+ | * B: “Enable Fertilizer Flow Rate Alarm” – Tick to enable Flow Rate Alarm set on Fertilizer | ||
+ | * C: “Flow Fertilizer Rate Error (%)” – Enter percentage Flow Rate allowed to be higher than expected before alarm is triggered | ||
+ | * Note: this percentage is the inverted; meaning if the expected Flow Rate is 100L/h, & Error is set to 80%, the alarm will be triggered on 100L/h + 20% = 120L/h | ||
+ | * D: “Alarm on EC Error” – Tick this box to enable alarm on EC Error | ||
+ | * E: “Alarm on PH Error” – Tick this box to enable alarm on PH Error | ||
+ | * F: “Fertilizer Alarm Duration Threshold (sec)” – The duration of time allowed for the Fertilizer programs values to be higher than margins allow before the alarm is triggered | ||
+ | * G: “Uncontrolled Alarm Amount (L)” – Max Volume of Fertilizer allowed to pass during one dose before alarm is triggered | ||
+ | * This alarm is for when the Fert Valve does not close (overdosing) | ||
+ | * Or when there is a leak | ||
+ | |||
+ | ====Fertilizer Pump Alarms==== | ||
+ | * H: “Fert Pump Start Delay (sec)” – Enter the pump start delay here | ||
+ | * I: “Fert Pump Alarm Sensor” – Select the relevant sensor from the dropdown list | ||
+ | * J: “Fert Pump Alarm Min” – Enter the min value allowed for sensor selected | ||
+ | * K: “Fert Pump Alarm Max” – Enter the max value allowed for sensor selected | ||
+ | |||
+ | =====Output Control===== | ||
+ | {{ : | ||
+ | * A: “Max Catchup (%)” – | ||
+ | * B: “Output Rate Control” | ||
+ | * “Always On” – used during batching, keeps the dosing valve open | ||
+ | * “Analog VSD Output” – | ||
+ | * “Duty Cycle” – used during proportional dosing, opens & closed the dosing valves based on values entered in C – E | ||
+ | * “Pulse Frequency” – | ||
+ | * “On/Off Delay” – used during proportional dosing, opens & closed the dosing valves based on values entered in C - E | ||
+ | * C: “Min Injector Off Delay (sec)” – | ||
+ | * D: “Min Injector On Delay (sec)” – | ||
+ | * E: “Control Cycle Duration (sec)” – | ||
+ | |||
+ | ======Adding Fertilizer to Valve Program====== | ||
+ | |||
+ | =====Adding a Fertilizer Program to a Step===== | ||
+ | Each “Step” has provision to add Fert Programs. | ||
+ | {{ : | ||
+ | |||
+ | * A: To add a Fertilizer program to the Valve Program, click on the “+” | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | * As seen above, you can now enter the following specifications: | ||
+ | * " | ||
+ | * " | ||
+ | * " | ||
+ | * " | ||
+ | * " | ||