programs:fertilizer_programs
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| programs:fertilizer_programs [2023/02/24 07:34] – marilisebester_gmail.com | programs:fertilizer_programs [2023/03/01 09:15] (current) – [Adding a Fertilizer Program to a Step] marilisebester_gmail.com | ||
|---|---|---|---|
| Line 52: | Line 52: | ||
| - | ====Flow Sensor==== | + | =====Flow Sensor===== |
| {{ : | {{ : | ||
| * A: “Fertilizer Tank Level Sensor” – Select the relevant Tank Level Sensor from the dropdown list | * A: “Fertilizer Tank Level Sensor” – Select the relevant Tank Level Sensor from the dropdown list | ||
| Line 66: | Line 66: | ||
| * G: “Mainline Flow Sensor” – Select the relevant Mainline Flow Sensor from the dropdown list | * G: “Mainline Flow Sensor” – Select the relevant Mainline Flow Sensor from the dropdown list | ||
| - | ====Agitating==== | + | =====Agitating===== |
| {{ : | {{ : | ||
| Line 83: | Line 83: | ||
| * H: “Agitation Program” - | * H: “Agitation Program” - | ||
| + | =====EC Control===== | ||
| + | The values entered here for EC min & Max are used for the EC Alarms if the Enable Alarm on EC Critical is active | ||
| + | {{ : | ||
| + | |||
| + | * A: “EC Min” – Enter the min EC value allowed | ||
| + | * B: “EC Target” – Enter the Target EC value | ||
| + | * C: “EC Max” – Enter the max EC value allowed | ||
| + | * D: “EC Compensation (%)” – | ||
| + | * E: “EC Compensation Adjustment (%)” - | ||
| + | |||
| + | =====Alarms===== | ||
| + | {{ : | ||
| + | |||
| + | ====Fertilizer Flow Rate Alarms==== | ||
| + | * A: “Alarm on Low Tank Level” – Tick to enable alarm on Low Tank Level | ||
| + | * B: “Enable Fertilizer Flow Rate Alarm” – Tick to enable Flow Rate Alarm set on Fertilizer | ||
| + | * C: “Flow Fertilizer Rate Error (%)” – Enter percentage Flow Rate allowed to be higher than expected before alarm is triggered | ||
| + | * Note: this percentage is the inverted; meaning if the expected Flow Rate is 100L/h, & Error is set to 80%, the alarm will be triggered on 100L/h + 20% = 120L/h | ||
| + | * D: “Alarm on EC Error” – Tick this box to enable alarm on EC Error | ||
| + | * E: “Alarm on PH Error” – Tick this box to enable alarm on PH Error | ||
| + | * F: “Fertilizer Alarm Duration Threshold (sec)” – The duration of time allowed for the Fertilizer programs values to be higher than margins allow before the alarm is triggered | ||
| + | * G: “Uncontrolled Alarm Amount (L)” – Max Volume of Fertilizer allowed to pass during one dose before alarm is triggered | ||
| + | * This alarm is for when the Fert Valve does not close (overdosing) | ||
| + | * Or when there is a leak | ||
| + | |||
| + | ====Fertilizer Pump Alarms==== | ||
| + | * H: “Fert Pump Start Delay (sec)” – Enter the pump start delay here | ||
| + | * I: “Fert Pump Alarm Sensor” – Select the relevant sensor from the dropdown list | ||
| + | * J: “Fert Pump Alarm Min” – Enter the min value allowed for sensor selected | ||
| + | * K: “Fert Pump Alarm Max” – Enter the max value allowed for sensor selected | ||
| + | |||
| + | =====Output Control===== | ||
| + | {{ : | ||
| + | * A: “Max Catchup (%)” – | ||
| + | * B: “Output Rate Control” | ||
| + | * “Always On” – used during batching, keeps the dosing valve open | ||
| + | * “Analog VSD Output” – | ||
| + | * “Duty Cycle” – used during proportional dosing, opens & closed the dosing valves based on values entered in C – E | ||
| + | * “Pulse Frequency” – | ||
| + | * “On/Off Delay” – used during proportional dosing, opens & closed the dosing valves based on values entered in C - E | ||
| + | * C: “Min Injector Off Delay (sec)” – | ||
| + | * D: “Min Injector On Delay (sec)” – | ||
| + | * E: “Control Cycle Duration (sec)” – | ||
| + | |||
| + | ======Adding Fertilizer to Valve Program====== | ||
| + | |||
| + | =====Adding a Fertilizer Program to a Step===== | ||
| + | Each “Step” has provision to add Fert Programs. | ||
| + | {{ : | ||
| + | |||
| + | * A: To add a Fertilizer program to the Valve Program, click on the “+” | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | * As seen above, you can now enter the following specifications: | ||
| + | * " | ||
| + | * " | ||
| + | * " | ||
| + | * " | ||
| + | * " | ||
programs/fertilizer_programs.1677224065.txt.gz · Last modified: 2023/02/24 07:34 by marilisebester_gmail.com