programs:fertilizer_programs

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
programs:fertilizer_programs [2023/02/24 07:37] – [EC Control] marilisebester_gmail.comprograms:fertilizer_programs [2023/03/01 09:15] (current) – [Adding a Fertilizer Program to a Step] marilisebester_gmail.com
Line 92: Line 92:
   * D: “EC Compensation (%)” –    * D: “EC Compensation (%)” – 
   * E: “EC Compensation Adjustment (%)” -    * E: “EC Compensation Adjustment (%)” - 
 +
 +=====Alarms=====
 +{{ :programs:fert_alarms.png?nolink&400|}}
 +
 +====Fertilizer Flow Rate Alarms====
 +  * A: “Alarm on Low Tank Level” – Tick to enable alarm on Low Tank Level
 +  * B: “Enable Fertilizer Flow Rate Alarm” – Tick to enable Flow Rate Alarm set on Fertilizer
 +  * C: “Flow Fertilizer Rate Error (%)” – Enter percentage Flow Rate allowed to be higher than expected before alarm is triggered
 +    * Note: this percentage is the inverted; meaning if the expected Flow Rate is 100L/h, & Error is set to 80%, the alarm will be triggered on 100L/h + 20% = 120L/h
 +  * D: “Alarm on EC Error” – Tick this box to enable alarm on EC Error
 +  * E: “Alarm on PH Error” – Tick this box to enable alarm on PH Error
 +  * F: “Fertilizer Alarm Duration Threshold (sec)” – The duration of time allowed for the Fertilizer programs values to be higher than margins allow before the alarm is triggered
 +  * G: “Uncontrolled Alarm Amount (L)” – Max Volume of Fertilizer allowed to pass during one dose before alarm is triggered 
 +    * This alarm is for when the Fert Valve does not close (overdosing)
 +    * Or when there is a leak 
 +
 +====Fertilizer Pump Alarms====
 +  * H: “Fert Pump Start Delay (sec)” – Enter the pump start delay here 
 +  * I: “Fert Pump Alarm Sensor” – Select the relevant sensor from the dropdown list 
 +  * J: “Fert Pump Alarm Min” – Enter the min value allowed for sensor selected
 +  * K: “Fert Pump Alarm Max” – Enter the max value allowed for sensor selected
 +
 +=====Output Control=====
 +{{ :programs:output_control.png?nolink&400|}}
 +  * A: “Max Catchup (%)” – 
 +  * B: “Output Rate Control” 
 +    *  “Always On” – used during batching, keeps the dosing valve open
 +    *  “Analog VSD Output” – 
 +    *  “Duty Cycle” – used during proportional dosing, opens & closed the dosing valves based on values entered in C – E
 +    *  “Pulse Frequency” – 
 +    *  “On/Off Delay” – used during proportional dosing, opens & closed the dosing valves based on values entered in C - E
 +  * C: “Min Injector Off Delay (sec)” – 
 +  * D: “Min Injector On Delay (sec)” – 
 +  * E: “Control Cycle Duration (sec)” – 
 +
 +======Adding Fertilizer to Valve Program======
 +
 +=====Adding a Fertilizer Program to a Step=====
 +Each “Step” has provision to add Fert Programs.
 +{{ :programs:fert_to_step.png?nolink&400 |}}
 +
 +  * A: To add a Fertilizer program to the Valve Program, click on the “+” 
 +
 +{{ :programs:fert_step_details.png?nolink&400 |}}
 +
 +  * As seen above, you can now enter the following specifications:
 +    * "Liters" - if dosing according to a batching method
 +    * "L/m3" - if dosing according to a proportional method
 +    * "EC" - if dosing to maintain a certain EC
 +    * "Pre-Delay" - duration of time that must pass from start of irrigation until fert program starts
 +    * "Post-Delay" - duration of time that the fert program must stop before the irrigation program stops 
  