Please note that to create a filter program, the following must be created first: | Please note that to create a filter program, the following must be created first: | ||
- | * " | + | * " |
- | * Valves for each of the backflush valves on the filter station | + | * Valves for each of the backflush valves on the filter station |
- | * DP (Differential Pressure) sensor | + | * DP (Differential Pressure) sensor |
+ | Should you require help in creating these, please contact your Farmsync Technician | ||
- | There are two scenarios that will be explained below: | + | =====Creating a Filter Program===== |
- | - Creating a Filter Program where flushing is managed by an external flush controller | + | |
- | - In this case, Farmsync only sends a start & end command | + | |
- | - Creating a Filter Program that issues all commands from Farmsync | + | |
- | - In this case all the flush times are set on Farmsync | + | |
- | + | ||
- | =====Using an external flush controller===== | + | |
{{ : | {{ : | ||
* A: “Name” – Enter a name for the Filter Program | * A: “Name” – Enter a name for the Filter Program | ||
Line 18: | Line 13: | ||
* C: “Station” – Select the relevant station that the filter is connected to from the dropdown list | * C: “Station” – Select the relevant station that the filter is connected to from the dropdown list | ||
+ | Press " | ||
{{ : | {{ : | ||
- | * A: “Enabled Automatic Start” | + | * A: “Enabled Automatic Start” |
- | * B: “Stop Remote Flush program when flushing done” – | + | * It is important to note that if this function is ticked, the Flush program will run permanently, |
+ | * If this option is taken, DO NOT add the Filter Flush program to a Valve Program, as this will cause a clash | ||
+ | * If you want the Filter Flush program to run ONLY when the valve program is running, then this function must NOT be ticked | ||
+ | * B: “Stop Remote Flush program when flushing done” – under construction | ||
* C: “Total Program Run Time (minutes)” – Enter the max Runtime (min) for the flush program | * C: “Total Program Run Time (minutes)” – Enter the max Runtime (min) for the flush program | ||
* D: “Flush Duration (seconds)” – Enter the time duration (sec) allowed for each filter to flush | * D: “Flush Duration (seconds)” – Enter the time duration (sec) allowed for each filter to flush | ||
* E: “Flush Time Duration (seconds)” – Enter the time allowed between filters to pass before the next filter flushes | * E: “Flush Time Duration (seconds)” – Enter the time allowed between filters to pass before the next filter flushes | ||
* F: “Minimum duration between flush operations (seconds)” – Enter the min time duration between flush cycles | * F: “Minimum duration between flush operations (seconds)” – Enter the min time duration between flush cycles | ||
- | * G: “Min Pressure to enable pressure flush (Bar)” – Enter the min pressure difference between in & outlet of filter allowed before | + | * G: “Min Pressure to enable pressure flush (Bar)” – Enter the min pressure difference between in & outlet of filter allowed before filter flushes |
- | * | + | * H: “Min Pressure to enable time flush (Bar)” – Enter the min pressure the system must supply for flushing to occur (refer to supplier filter specifications) |
- | * H: “Min Pressure to enable time flush (Bar)” – Enter the min pressure the system must supply for flushing to occur (refer to | + | * I: “Pressure Flush Delay (seconds)” – Enter the time (sec) allowed to pass for pressure difference to be higher than min before flush is enabled |
- | * | + | * J: “Flush Duration Delay (seconds)” – enter the duration of time that must past from when flushing is triggered before the flushing valves open (eg. allows time for Mainvalve to close) |
- | * I: “Pressure Flush Delay (seconds)” – Enter the time (sec) allowed to pass for pressure difference to be higher than min before | + | |
- | * flush is enabled | + | |
- | * J: “Flush Duration Delay (seconds)” – | + | |
* K: “Flush on Start” – When enabled, filter will flush when program starts | * K: “Flush on Start” – When enabled, filter will flush when program starts | ||
* L: “Flush on End” – When enabled, filter will flush when program stops | * L: “Flush on End” – When enabled, filter will flush when program stops | ||
* M: “Filter Start Delay (seconds)” – Duration of time allowed to pass after filter program has started before filter flushes | * M: “Filter Start Delay (seconds)” – Duration of time allowed to pass after filter program has started before filter flushes | ||
+ | See below example of flush program times explained: | ||
+ | {{ : | ||
+ | {{ : | ||
+ | |||
+ | {{ : | ||
+ | * A: “Flush Activated Sensor” – | ||
+ | * B: “Flush Active Port” – | ||
+ | * C: “Before Filter or Differential Pressure Sensor” – Select the relevant Pressure Sensor / DP Sensor from the dropdown list | ||
+ | * D: “After Filter Pressure Sensor” – Select the relevant Pressure Sensor from the dropdown list (if DP Sensor was selected in C, then this sensor can be left to "Not Set" | ||
+ | * E: “Remote Flush Program to Start when Flushing” – | ||
+ | * F: “Remote Pause / Resume program when flushing” – Select the relevant program that must be paused if the flushing sequence is initiated, this program will resume once the flushing program is completed | ||
+ | * G: “Mainline Control Valve” – Select the relevant Mainline Control Valve from the dropdown list, should one be present | ||
+ | * H: “Mainline Control Valve Close Delay” – Enter the duration of time allowed to pass from when filter flush is initiated before the Mainline Control Valve must close | ||
+ | * I: “Master Filter Program” – Select the relevant Filter program from the dropdown list | ||
+ | * J: “Auto Start from Master Filter Program” – Enable if current filter program must start the same time as the Master Filter Program | ||
+ | |||
+ | =====Flush Valves===== | ||
+ | {{ : | ||
+ | Choose from the dropdown lists below the relevant Flush Valves that were created for the Filter under “Setup_Manage Valves”; Provision has been made for 32 valves in total. |