Previous revision
programs:filter_programs [2023/03/08 06:11] marilisebester_gmail.comprograms:filter_programs [2023/03/08 06:23] (current) marilisebester_gmail.com
Line 2: Line 2:
  
 Please note that to create a filter program, the following must be created first: Please note that to create a filter program, the following must be created first:
-  * "Filter" Mainline +  * "Filter" Mainline - created under setup_mainlines 
-  * Valves for each of the backflush valves on the filter station +  * Valves for each of the backflush valves on the filter station - created under setup_manage valves 
-  * DP (Differential Pressure) sensor+  * DP (Differential Pressure) sensor - created under setup_all sensors 
 +Should you require help in creating these, please contact your Farmsync Technician
  
-There are two scenarios that will be explained below: +=====Creating a Filter Program=====
-  - Creating a Filter Program where flushing is managed by an external flush controller  +
-    - In this case, Farmsync only sends a start & end command +
-  - Creating a Filter Program that issues all commands from Farmsync +
-    - In this case all the flush times are set on Farmsync +
- +
-=====Using an external flush controller=====+
 {{ :programs:program_details1.png?nolink&400 |}} {{ :programs:program_details1.png?nolink&400 |}}
   * A: “Name” – Enter a name for the Filter Program   * A: “Name” – Enter a name for the Filter Program
Line 18: Line 13:
   * C: “Station” – Select the relevant station that the filter is connected to from the dropdown list   * C: “Station” – Select the relevant station that the filter is connected to from the dropdown list
  
 +Press "Save" in order to set the rest of the settings for this program
  
 {{ :programs:program_details2.png?nolink&400 |}} {{ :programs:program_details2.png?nolink&400 |}}
Line 53: Line 49:
   * J: “Auto Start from Master Filter Program” – Enable if current filter program must start the same time as the Master Filter Program   * J: “Auto Start from Master Filter Program” – Enable if current filter program must start the same time as the Master Filter Program
  
 +=====Flush Valves=====
 +{{ :programs:flush_valves.png?nolink&400 |}}
 +
 +Choose from the dropdown lists below the relevant Flush Valves that were created for the Filter under “Setup_Manage Valves”; Provision has been made for 32 valves in total.
programs/filter_programs.1678255881.txt.gz · Last modified: 2023/03/08 06:11 by marilisebester_gmail.com