Filter Program
Please note that to create a filter program, the following must be created first:
- “Filter” Mainline
 - Valves for each of the backflush valves on the filter station
 - DP (Differential Pressure) sensor
 
There are two scenarios that will be explained below:
- Creating a Filter Program where flushing is managed by an external flush controller
- In this case, Farmsync only sends a start & end command
 
 - Creating a Filter Program that issues all commands from Farmsync
- In this case all the flush times are set on Farmsync
 
 
Using an external flush controller
- A: “Name” – Enter a name for the Filter Program
 - B: “External Reference” – For Farmsync internal use only
 - C: “Station” – Select the relevant station that the filter is connected to from the dropdown list
 
- A: “Enabled Automatic Start”
- It is important to note that if this function is ticked, the Flush program will run permanently, meaning even when no Valve program is running
 - If this option is taken, DO NOT add the Filter Flush program to a Valve Program, as this will cause a clash
 - If you want the Filter Flush program to run ONLY when the valve program is running, then this function must NOT be ticked
 
 - B: “Stop Remote Flush program when flushing done” – under construction
 - C: “Total Program Run Time (minutes)” – Enter the max Runtime (min) for the flush program
 - D: “Flush Duration (seconds)” – Enter the time duration (sec) allowed for each filter to flush
 - E: “Flush Time Duration (seconds)” – Enter the time allowed between filters to pass before the next filter flushes
 - F: “Minimum duration between flush operations (seconds)” – Enter the min time duration between flush cycles
 - G: “Min Pressure to enable pressure flush (Bar)” – Enter the min pressure difference between in & outlet of filter allowed before filter flushes
 - H: “Min Pressure to enable time flush (Bar)” – Enter the min pressure the system must supply for flushing to occur (refer to supplier filter specifications)
 - I: “Pressure Flush Delay (seconds)” – Enter the time (sec) allowed to pass for pressure difference to be higher than min before flush is enabled
 - J: “Flush Duration Delay (seconds)” – enter the duration of time that must past from when flushing is triggered before the flushing valves open (eg. allows time for Mainvalve to close)
 - K: “Flush on Start” – When enabled, filter will flush when program starts
 - L: “Flush on End” – When enabled, filter will flush when program stops
 - M: “Filter Start Delay (seconds)” – Duration of time allowed to pass after filter program has started before filter flushes
 
See below example of flush program explained: